Illustration of a step-free entrance with a level threshold, a wide front door and a ground floor WC in a house section

Approved Document M: Part M access rules for homes in England

Approved Document M is the government guidance on Part M of the building regulations: access to and use of buildings. For homes it sets three standards, M4(1), M4(2) and M4(3), and in London the planning system decides which one a new home must meet. Here is what Part M asks for, and what it means when you extend or convert a house.

What Approved Document M covers

Part M is one of the parts of Schedule 1 to the Building Regulations 2010. The approved document comes in two volumes. Volume 1 covers dwellings, with the requirements M4(1), M4(2) and M4(3); the current Volume 1 is the 2015 edition incorporating 2016 amendments. Volume 2 covers buildings other than dwellings, such as shops, offices and the common parts of some buildings, and points to BS 8300 for design detail. Some people shorten the name to Doc M or Part M regs; it is the same document.

Like every approved document, it is guidance: the legal requirement is in the regulations, and you may meet it another way if you can show the result is as good. In practice building control checks against the approved document.

M4(1), M4(2) and M4(3): the three standards for new homes

  • M4(1) Category 1, visitable dwellings: the default for a new home: most people, including wheelchair users, can approach and enter it and use the WC on the entrance storey.
  • M4(2) Category 2, accessible and adaptable dwellings: step-free access, wider doors and circulation space, and a home that can be adapted later. People sometimes type it as M42.
  • M4(3) Category 3, wheelchair user dwellings: a home built for a wheelchair user, or designed so it can be adapted for one.

M4(2) and M4(3) are optional requirements: they apply only when a planning condition says a home must meet them. In London, Policy D7 of the London Plan asks that at least 10 per cent of new homes meet M4(3) and the rest meet M4(2), so most new London homes are built to M4(2) or better. In 2022 the government said it would make M4(2) the minimum standard for all new homes in England once the regulations are changed; check GOV.UK for the date.

Closer rear view of the dormer, KRAMAN Ltd, LondonExposed timber ceiling joists and brickwork during the Brockley house renovation, KRAMAN Ltd, LondonGalley kitchen in Leyton with white gloss units, a built-in oven and a door to the garden, KRAMAN Ltd, LondonCloakroom in East Finchley with a close-coupled WC, a heated towel rail and white tiles, KRAMAN Ltd, London

Part M and extensions, loft conversions and renovations

Requirement M4(1) does not apply to an extension to a dwelling, so a rear extension or a loft conversion does not have to be built to the visitable standard. The work should still not leave the house less compliant with Part M than it was before; for example, a new extension should not make the route to the entrance harder to use. Our house extensions often add a step-free door to the garden and a wider opening between rooms, which is good practice; Part M does not demand it.

When a building is converted into flats, the new homes are new dwellings in their own right, and the council can attach M4(2) or M4(3) conditions to the planning permission.

Downstairs toilets, sockets and switches

For a new home built to M4(1), the guidance asks for a WC on the entrance storey, or on the principal storey if the entrance storey has no habitable rooms, and for switches and sockets serving habitable rooms to sit between 450 mm and 1200 mm above the floor. Adding a downstairs toilet to an existing house is not a Part M requirement; the drainage, ventilation and electrical work still follow Parts H, F and P, as our bathroom renovation post explains.

Timber vanity unit with two countertop basins during fitting, KRAMAN Ltd, LondonWhite mosaic laid across the shower base and bathroom floor, KRAMAN Ltd, LondonCompact cloakroom with a tiled concealed-cistern enclosure, KRAMAN Ltd, LondonTimber rafters forming the hipped roof of the Highgate extension during construction, KRAMAN Ltd, London

Accessible adaptations to an existing home

A level-access shower, grab rails, a wider door or a ramp to the front door can be built in any house. Where the work changes structure or drainage, the relevant parts of the building regulations apply; a ramp at the front may also need planning permission if it is raised. A council Disabled Facilities Grant can help with the cost for an eligible disabled occupant; the council assesses each case.

Questions people ask

What is Approved Document M?

The government guidance on Part M of the Building Regulations 2010, access to and use of buildings: Volume 1 covers dwellings and Volume 2 covers other buildings.

Does Part M apply to a house extension?

Requirement M4(1) does not apply to an extension to a dwelling, but the extension should not make the house less compliant with Part M than it was before.

What is M4(2)?

Category 2, accessible and adaptable dwellings: an optional standard with step-free access and space to adapt the home later, which applies when a planning condition requires it. Most new London homes are built to it under the London Plan.

Do I need a downstairs toilet under Part M?

A new home built to M4(1) needs a WC on the entrance storey; adding one to an existing house is your choice, and the drainage, ventilation and electrics follow the other parts of the regulations.

What height should sockets be under Part M?

In a new home to M4(1), switches and sockets serving habitable rooms sit between 450 mm and 1200 mm above the finished floor.

Call us