Approved Document C: Part C damp proofing, radon and ground floors

Approved Document C is the guidance on Part C of the building regulations: site preparation and resistance to contaminants and moisture. It keeps damp out of new walls and floors and gas out of new buildings, and it is the part that explains the air bricks along the bottom of every Victorian terrace.

What building regulations Part C covers

Part C has two requirements: preparing the site and resisting contaminants, including radon (C1), and resisting moisture from the ground, rain and condensation (C2). The current document is the 2004 edition incorporating 2010 and 2013 amendments.

Damp proof courses and ground floors

A new wall needs a damp proof course at least 150 mm above the outside ground level, so rain splashing up and wet ground do not soak into it. A new solid floor has a damp proof membrane linked to the damp proof course. In an extension, the new floor and walls join the old house, and the damp proofing must be continuous at that junction; raising a patio against the house so the ground covers the damp proof course is a common cause of damp.

Air bricks and suspended timber floors

Many London houses have suspended timber ground floors with a void underneath. That void must be ventilated, through openings in two opposite external walls, sized at least 1500 mm² per metre run of wall or 500 mm² per square metre of floor, whichever is greater. When an extension covers the old air bricks, the ventilation is carried through with ducts or new vents, or the floor is replaced. Blocking air bricks with paving or render leads to rot.

Basement floor work in progress, with pipework visible before the floor covering, KRAMAN Ltd, LondonFinished basement media wall with dark fitted panels, shelving and illuminated recess, KRAMAN Ltd, LondonSteel beam beneath the existing timber floor during the Leytonstone basement works, KRAMAN Ltd, LondonBasement conversion with a lightwell in Leytonstone, photograph 8, KRAMAN Ltd

Cavity trays, weep holes and condensation

Where a cavity wall is interrupted, over a window or where an extension roof meets the old wall, a cavity tray catches water in the cavity and weep holes let it out. In roofs, Part C also deals with condensation: a cold roof needs ventilation above the insulation, and a warm roof keeps the deck warm with insulation above it and a vapour control layer below.

Radon and contaminated land

Radon is a natural radioactive gas from the ground. In areas where it is a risk, new buildings and extensions need radon protection, from a gas-resistant membrane to full protection with a sump. Most of London is a low radon area; the UK radon map shows the level for an address. Sites with a history of industrial use may need a ground investigation before building.

Questions people ask

What is Approved Document C?

The government guidance on Part C of the Building Regulations 2010: site preparation and resistance to contaminants such as radon, and to moisture.

How high must a damp proof course be?

At least 150 mm above the outside ground level for a new wall.

Can I cover air bricks with an extension?

Only if the subfloor ventilation is kept, for example with ducts through the new floor to new vents, or the suspended floor is replaced with a solid one.

Do I need radon protection in London?

Most of London is a low radon area; check the UK radon map for the address, and building control will say if protection is needed.