A loft conversion on a two-storey house creates a room more than 4.5 metres above the ground, too high to escape from by a window. So the stair becomes the escape route, and Part B asks for:
- A protected stairway from the loft down to an exit, enclosed by fire-resisting walls and doors.
- Fire-resisting doors, rated at least E 20 and still sold as FD20, on the habitable rooms that open onto the stair.
- Mains-powered smoke alarms, linked together, in the circulation spaces on every storey: a Grade D2, Category LD3 system under BS 5839-6 as the minimum.
- A fire-resisting floor between the loft and the storey below.
An open-plan ground floor, where the stair rises from the living room, needs a different solution, such as a new enclosure or sprinklers with fire separation; building control agrees it at the design stage. Our loft conversion page explains how we plan it.