# Building regulations approved documents A to T: what each part covers

Source: https://kraman.co.uk/guides/approved-documents/
Updated: 25 November 2026

The approved documents are the government guidance on how to meet each part of the building regulations in England. There is one for each part, from Part A for structure to Part T for toilets, plus one for Regulation 7 on materials and workmanship. This page lists them all and links to our guide on each part that comes up in house work.

By [KRAMAN Ltd](https://kraman.co.uk/about/), builders in London since 2006.

## Building control approved documents: what an approved document is

The Building Regulations 2010 set requirements in Schedule 1, grouped into lettered parts. Each approved document explains one part and gives ways to meet it. Following the approved document is the usual way to show building control the work complies, but it is not compulsory: an engineer or designer can show compliance another way. GOV.UK publishes every approved document free, together with a merged version of them all.

## The approved documents, part by part

- [Part A: structure](https://kraman.co.uk/guides/approved-document-a/). Beams, foundations, loft floors and walls.
- [Part B: fire safety](https://kraman.co.uk/guides/approved-document-b/). Volume 1 for dwellings, Volume 2 for other buildings.
- [Part C: site preparation and resistance to contaminants and moisture](https://kraman.co.uk/guides/approved-document-c/). Damp proofing, air bricks, radon.
- Part D: toxic substances. Fumes from urea formaldehyde foam cavity wall insulation.
- [Part E: resistance to the passage of sound](https://kraman.co.uk/guides/approved-document-e/). Walls and floors between homes.
- [Part F: ventilation](https://kraman.co.uk/guides/approved-document-f/). Extract fans, trickle vents and purge ventilation.
- [Part G: sanitation, hot water safety and water efficiency](https://kraman.co.uk/guides/approved-document-g/).
- [Part H: drainage and waste disposal](https://kraman.co.uk/guides/approved-document-h/). Drains, sewers, soakaways and bin stores.
- [Part J: combustion appliances and fuel storage](https://kraman.co.uk/guides/approved-document-j/). Stoves, boilers, flues and carbon monoxide alarms.
- [Part K: protection from falling, collision and impact](https://kraman.co.uk/guides/approved-document-k/). Stairs, guarding and safety glass.
- [Part L: conservation of fuel and power](https://kraman.co.uk/guides/approved-document-l/). Insulation, windows and heating.
- [Part M: access to and use of buildings](https://kraman.co.uk/guides/approved-document-m/). M4(1), M4(2) and M4(3).
- [Part O: overheating](https://kraman.co.uk/guides/approved-document-o/). New homes only.
- [Part P: electrical safety in dwellings](https://kraman.co.uk/guides/approved-document-p/).
- Part Q: security in dwellings. Doors and windows of new homes that resist attack, usually to PAS 24.
- Part R: infrastructure for electronic communications. Ducts and a gigabit-capable connection for new homes.
- Part S: infrastructure for charging electric vehicles. A charge point for new homes with parking.
- Part T: toilet accommodation, added in 2024 for buildings other than dwellings.

There is no Part I or Part N: Part N on glazing was merged into Part K in 2013.

## Regulation 7 and Regulation 38

Some rules sit in the body of the regulations, outside Schedule 1. Regulation 7 requires building work to be carried out with adequate and proper materials, appropriate to the circumstances, in a workmanlike manner; its approved document explains what that means for products and workmanship. Regulation 7(2) bans combustible materials in the external walls of certain residential buildings over 18 metres. Regulation 38 requires fire safety information to be handed to the responsible person when a building covered by the Fire Safety Order is finished.

## Which parts apply to your project

A typical London [loft conversion](https://kraman.co.uk/services/loft-conversion-london/) touches Parts A, B, C, F, K, L and P, and Part G and H if it has an ensuite. A [rear extension](https://kraman.co.uk/services/house-extension-london/) touches A, B, C, F, H, K, L and P. A house converted into flats adds Part E and more of Part B. Building control looks at all of them together; our guide to [building control](https://kraman.co.uk/guides/building-control/) explains how the checks work.

## Questions people ask

### How many approved documents are there?

One for each part of Schedule 1, Part A to Part T without I and N, plus one for Regulation 7 on materials and workmanship.

### Are approved documents law?

No. The law is the Building Regulations 2010; the approved documents are guidance on meeting it, and following them is the usual way to show compliance.

### Where can I download the approved documents?

Free from GOV.UK, one by one or as a single merged document.

### What is Regulation 7 of the building regulations?

The requirement that building work uses adequate and proper materials and is carried out in a workmanlike manner; Regulation 7(2) also bans combustible materials in the external walls of certain tall residential buildings.

## Read next

### [Building regulations questions answered: the Building Regulations 2010 for house work](https://kraman.co.uk/blog/building-regulations-questions/)

### [Building control in London: council or approver, full plans or building notice, inspections](https://kraman.co.uk/guides/building-control/)

### [Approved Document B: fire safety rules for loft conversions, extensions and flats](https://kraman.co.uk/guides/approved-document-b/)

Sources: [GOV.UK: Approved Documents](https://www.gov.uk/government/collections/approved-documents) · [legislation.gov.uk: The Building Regulations 2010, Schedule 1](https://www.legislation.gov.uk/uksi/2010/2214/schedule/1) · [GOV.UK: material and workmanship, Approved Document 7](https://www.gov.uk/government/publications/material-and-workmanship-approved-document-7).