# Approved Document K: Part K stair, guarding and glazing rules for homes

Source: https://kraman.co.uk/guides/approved-document-k/
Updated: 25 November 2026

Approved Document K is the guidance on Part K of the building regulations: protection from falling, collision and impact. For a homeowner it is the rulebook for stairs, balustrades and safety glass, and it often decides where the stair to a loft conversion can go.

By [KRAMAN Ltd](https://kraman.co.uk/about/), builders in London since 2006.

## What Part K covers

Part K covers stairs, ladders and ramps (K1), protection from falling at the edges of floors, balconies and roofs (K2), vehicle barriers (K3), protection against impact with glazing (K4), additional glazing provisions for buildings other than dwellings (K5) and protection against impact from and trapping by doors (K6). The rules on safety glass were in a separate Part N until 2013, when they moved into Part K.

## Building regs for stairs in a house

For a private stair, one inside a single home, the approved document gives these figures:

- Rise of each step: no more than 220 mm.
- Going of each step: at least 220 mm.
- Pitch: no more than 42 degrees.
- Headroom: 2 metres over the whole stair and landings. In a loft conversion, where that is not possible, 1.9 metres at the centre of the stair, falling to 1.8 metres at the side, is accepted.
- Open risers must not let a 100 mm sphere pass through.

The headroom is usually what decides the stair position in a [loft conversion](https://kraman.co.uk/services/loft-conversion-london/): the new stair goes where the roof is highest, often above the existing stair. A space saver stair, with alternating treads, is accepted only where there is no room for a normal stair and it serves one habitable room. Spiral and helical stairs follow BS 5395-2.

## Handrails and guarding

A stair needs a handrail on at least one side if it is less than 1 metre wide, and on both sides if it is wider. In a home, guarding on stairs, landings and the edges of internal floors is at least 900 mm high; on external balconies and roof edges it is 1100 mm. Gaps in guarding must not let a 100 mm sphere through, and it must not be easy to climb where children use the building. These rules apply to balcony railings, Juliet balconies and the edge of a mezzanine floor.

## Safety glass

Glass in critical locations must break safely or resist impact: in a door or the panel beside it up to 1500 mm above the floor, and in a wall up to 800 mm above the floor. Toughened or laminated glass marked to the right standard meets this. A FENSA or other registered installer fitting replacement windows and doors takes care of it and certifies the work.

## Questions people ask

### What is the maximum stair rise under Part K?

For a private stair in a home: a rise of no more than 220 mm, a going of at least 220 mm and a pitch of no more than 42 degrees.

### What headroom does a loft conversion stair need?

2 metres where possible; in a loft conversion 1.9 metres at the centre of the stair, falling to 1.8 metres at the side, is accepted.

### How high must a balustrade be in a house?

At least 900 mm on stairs, landings and internal floor edges, and 1100 mm on external balconies and roof edges.

### Do I need building regulations to replace a staircase?

Replacing a stair like for like is often treated as a repair, but a new stair in a new position, or one in a loft conversion, is building work that must meet Part K.

## Read next

### [Building regulations approved documents A to T: what each part covers](https://kraman.co.uk/guides/approved-documents/)

### [Approved Document B: fire safety rules for loft conversions, extensions and flats](https://kraman.co.uk/guides/approved-document-b/)

### [Loft conversion cost in London: answers to the questions people ask](https://kraman.co.uk/blog/loft-conversion-cost-questions/)

Sources: [GOV.UK: protection from falling, collision and impact, Approved Document K](https://www.gov.uk/government/publications/protection-from-falling-collision-and-impact-approved-document-k) · [GOV.UK: Approved Documents](https://www.gov.uk/government/collections/approved-documents).