# Approved Document J: Part J rules for stoves, fireplaces, flues and boilers

Source: https://kraman.co.uk/guides/approved-document-j/
Updated: 25 November 2026

Approved Document J is the guidance on Part J of the building regulations: combustion appliances and fuel storage. In a London house it covers the wood burning stove in a reopened fireplace, a new gas or oil boiler and its flue, and the carbon monoxide alarm that must go with them.

By [KRAMAN Ltd](https://kraman.co.uk/about/), builders in London since 2006.

## What Part J covers

Part J has seven requirements: an air supply for appliances that burn fuel (J1), safe discharge of the products of combustion through a flue (J2), warning of carbon monoxide (J3), protection of the building from heat and fire (J4), a notice plate with information about the flue and hearth (J5), and protection of liquid fuel storage from fire and of the ground and water from oil spills (J6 and J7). The current document is the 2010 edition incorporating 2010, 2013 and 2022 amendments.

## Wood burning stoves and open fires

Installing a stove is building work under Part J. The stove needs a constructional hearth of non-combustible material, clearances to combustible materials such as a timber mantel or beams, a flue that is sound and the right size, often a new flexible liner inside an old chimney, and permanent ventilation where the stove needs it. A HETAS registered installer can self-certify the work; otherwise it goes through building control. In London, most boroughs are smoke control areas, so a stove must be a Defra exempt appliance and burn authorised fuel unless it is an approved smokeless design.

## Carbon monoxide alarms

Since 1 October 2022, a carbon monoxide alarm should be fitted in the room whenever a new or replacement fixed combustion appliance is installed, whether it burns solid fuel, gas or oil. Gas cookers are the exception. The alarm meets BS EN 50291 and sits on the ceiling at least 300 mm from any wall, or on a wall above the height of any door or window and within the distances the approved document gives from the appliance.

## Boilers, flues and oil tanks

A gas boiler must be installed by a Gas Safe registered engineer, who notifies the work. Its flue terminal has to sit at set distances from windows, doors, the boundary and the eaves, which often decides where a boiler can go in a loft or kitchen extension. An oil tank needs fire protection and a bund where the approved document sets it, depending on its size and its distance from the building and the boundary.

## Chimney breasts and chimney stacks

If you take out a chimney breast, the chimney above still needs support, often with steel gallows brackets or a beam, under Part A; if the fireplace stays in use, Part J governs the flue and hearth. Our [chimney breast removal post](https://kraman.co.uk/blog/chimney-breast-removal/) covers chimney breast removal, and our [permitted development guide](https://kraman.co.uk/guides/permitted-development-rights/) covers removing a chimney stack.

## Questions people ask

### What is Approved Document J?

The government guidance on Part J of the Building Regulations 2010: combustion appliances and fuel storage systems, including stoves, boilers, flues, hearths and carbon monoxide alarms.

### Does a wood burning stove need building regulations approval?

Yes. A HETAS registered installer can self-certify it; otherwise the installation goes through building control.

### When is a carbon monoxide alarm required?

Since 1 October 2022, whenever a new or replacement fixed combustion appliance burning solid fuel, gas or oil is installed in a home, gas cookers excepted.

### Can I use a wood burner in London?

Most of London is a smoke control area, so the stove must be a Defra exempt appliance or burn authorised smokeless fuel.

## Read next

### [Building regulations approved documents A to T: what each part covers](https://kraman.co.uk/guides/approved-documents/)

### [Chimney breast removal: cost, regulations and support for the chimney above](https://kraman.co.uk/blog/chimney-breast-removal/)

### [Approved Document F: Part F ventilation for kitchens, bathrooms and extensions](https://kraman.co.uk/guides/approved-document-f/)

Sources: [GOV.UK: combustion appliances and fuel storage systems, Approved Document J](https://www.gov.uk/government/publications/combustion-appliances-and-fuel-storage-systems-approved-document-j) · [GOV.UK: smoke control areas, the rules](https://www.gov.uk/smoke-control-area-rules) · [Gas Safe Register](https://www.gassaferegister.co.uk/).