# Approved Document B: fire safety rules for loft conversions, extensions and flats

Source: https://kraman.co.uk/guides/approved-document-b/
Updated: 25 November 2026

Approved Document B is the guidance on Part B of the building regulations, fire safety. In a London house it comes up most in a loft conversion, which adds a floor that people must be able to escape from, and in extensions built close to a neighbour. Here is what Part B asks for in houses and flats.

By [KRAMAN Ltd](https://kraman.co.uk/about/), builders in London since 2006.

## Volume 1 and Volume 2

Part B covers means of warning and escape (B1), internal fire spread through linings and structure (B2 and B3), external fire spread (B4) and access for the fire service (B5). Approved Document B Volume 1 deals with dwellings: houses, flats and their common parts. Volume 2 deals with buildings other than dwellings. GOV.UK lists the current edition of each volume with its amendments; check it there before you rely on a figure.

## Fire safety in a loft conversion

A loft conversion on a two-storey house creates a room more than 4.5 metres above the ground, too high to escape from by a window. So the stair becomes the escape route, and Part B asks for:

- A protected stairway from the loft down to an exit, enclosed by fire-resisting walls and doors.
- Fire-resisting doors, rated at least E 20 and still sold as FD20, on the habitable rooms that open onto the stair.
- Mains-powered smoke alarms, linked together, in the circulation spaces on every storey: a Grade D2, Category LD3 system under BS 5839-6 as the minimum.
- A fire-resisting floor between the loft and the storey below.

An open-plan ground floor, where the stair rises from the living room, needs a different solution, such as a new enclosure or sprinklers with fire separation; building control agrees it at the design stage. Our [loft conversion page](https://kraman.co.uk/services/loft-conversion-london/) explains how we plan it.

## Escape windows

A habitable room on the first floor, and a ground floor room that does not open onto a hall leading to an exit, needs an escape window or another route out. An escape window has an openable area of at least 0.33 square metres, at least 450 mm high and 450 mm wide, with the bottom of the opening no more than 1100 mm above the floor. These are the bedroom window fire escape regulations people search for, and they matter when you replace windows or build a ground floor extension that cuts off an existing room.

## Extensions near the boundary

Part B4 limits fire spreading from one house to the next. A wall built close to the boundary must resist fire, and the area of windows and doors in it is limited, so a side return extension on the boundary usually has a solid wall to the neighbour and its glass at the rear and in the roof. A roof covering near a boundary must also resist fire from outside.

## Flats, fire doors and conversions

In a block of flats, each flat entrance door is a fire door, usually self-closing, and the common stair and lobbies form a protected route. Since 23 January 2023 the Fire Safety (England) Regulations 2022 require the responsible person in a block over 11 metres to check flat entrance doors every year on a best endeavours basis and communal fire doors every quarter. When a house is converted into flats, the separating walls and floors between the flats must resist fire, and a new stair or lobby arrangement is often needed.

## Questions people ask

### What is Approved Document B?

The government guidance on Part B of the Building Regulations 2010, fire safety: Volume 1 covers dwellings and Volume 2 covers other buildings.

### Do I need fire doors in a loft conversion?

Yes, usually: the habitable rooms opening onto the stair need fire-resisting doors rated at least E 20 (FD20), so the stair stays usable as an escape route.

### What size must a fire escape window be?

An openable area of at least 0.33 m², at least 450 mm high and 450 mm wide, with the bottom of the opening no more than 1100 mm above the floor.

### What smoke alarms does a loft conversion need?

Mains-powered smoke alarms, linked together, in the circulation spaces on each storey: Grade D2, Category LD3 under BS 5839-6 as the minimum in Approved Document B.

### Are flat front doors fire doors?

In a block of flats, yes: each entrance door to a flat is a fire door, normally self-closing, and in buildings over 11 metres the responsible person must check them every year.

## Read next

### [Building regulations approved documents A to T: what each part covers](https://kraman.co.uk/guides/approved-documents/)

### [Approved Document K: Part K stair, guarding and glazing rules for homes](https://kraman.co.uk/guides/approved-document-k/)

### [Loft conversion cost in London: answers to the questions people ask](https://kraman.co.uk/blog/loft-conversion-cost-questions/)

Sources: [GOV.UK: fire safety, Approved Document B](https://www.gov.uk/government/publications/fire-safety-approved-document-b) · [GOV.UK: Fire Safety (England) Regulations 2022, fact sheet on fire doors](https://www.gov.uk/government/publications/fire-safety-england-regulations-2022/fact-sheet-fire-doors-regulation-10).